NLF-200B
Continuous Positive Airway Pressure (CPAP) nurtures and supports infant breathing by providing respiratory support throughout the respiratory cycle.
Application
Continuous Positive Airway Pressure (CPAP) nurtures and supports infant breathing by providing respiratory support throughout the respiratory cycle.
Neo-CPAP System maintains the infant’s functional residual capacity by helping to prevent airway closure.
The NLF-200A Plus Neo-CPAP System features an ergonomic and uncluttered touch-screen interface, enabling the clinician to quickly and easy access the current patient status.
With the advantages of compact device, small footprint, saving energy and integrated high-performance in operation.
This makes it an ideal companion for your smallest patients in the Neonatal Intensive Care Units (NICU), emergency ward, delivery room and other departments.
Trust point
- 10.4 Inch TFT touch LCD screen displays the ventilation parameters, alarm information and oscillogram.
- Better work of breathing: Integration breathing circuit design, maximize lung protection and breathing support.
- Increase clinician’s confidence in Neo-CPAP: Multiple parameters monitoring interface, makes every parameter clear, let users know the patient conditions in all aspects.
- Real time pressure-time oscillogram and high precision O2 concentration detection function included, reduces length of stay in hospital.
- Built-in air and oxygen blender, ensures stable oxygen concentration.
- Stable and low noise air compressor creates quiet work environment for doctors, can be used for 2-3 Neo-CPAP Systems together.
TECHNICAL SPECIFICATION | Value | TECHNICAL SPECIFICATION | Value |
---|---|---|---|
Ventilation mode | Alarm and protection | ||
CPAP, NIPPV, HFNC, MANUAL, NCPAP | The AC power failure alarm | Power failure or no connection | |
Internal battery backup low voltage alarm | < 11.3 ± 0.3 V | ||
Parameter | High oxygen concentration alarm | 16% ~ 100% | |
Oxygen concentration | Adjusting range: 21% ~ 100% | Low oxygen concentration alarm | 15% ~ 99% |
Monitoring range: 15% ~ 100% | High Airway pressure alarm | 1.5 kPa ~ 6k Pa | |
CPAP | Adjusting range: 0 cmH2O ~ 15 cmH2O | Low air input pressure alarm | < 200 kPa |
Monitoring range: 0 cmH2O ~ 60 cmH2O | Low oxygen input pressure alarm | < 200 kPa | |
Continuous flow | Adjusting range: 1 L/min ~ 20 L/min | Air and oxygen blender alarm | When any gas source lack |
Monitoring range: 0 L/min ~ 40 L/min | When differential pressure > 0.1m Pa | ||
Pressure monitoring | 0 cmH2O ~ 60 cmH2O | Compression pump alarm | Excess temperature |
Inhalation pressure | 3 cmH2O ~ 20 cmH2O | ||
Exhalation pressure | 1 cmH2O ~ 13 cmH2O | Working condition | |
Breath Frequency | Adjusting range: 1 /min ~ 120 /min | Gas source | O2, Air |
Monitoring range: 0 ~ 120 /min | Pressure | 280 kPa ~ 600 kPa | |
Inhalation time | Adjusting range: 0.1 s ~ 15 s | Voltage | 100 ~ 240 V |
Monitoring range: 0 s - 15 s | Power frequency | 50/60 Hz | |
Manual ventilation | Output flow: 3 L/min ± 25 L/min | ||
Air compressor | Continuous output flow: ≥ 25 L/min | Wooden case packing size | |
Peak output flow: ≥ 120 L/min | Main components | L 506 * W 566 * H 625 mm | |
G.W. | 38 KG | ||
Oscillogram | N.W. | 18 KG | |
P-T (pressure – time) | Air compressor | L 683* W 687 * H 1140 mm | |
Flow of oxygen, air and mixed gas | G.W. | 100 KG | |
Airway pressure oscillogram | N.W. | 65 KG |




To better ensure the safety of goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Wooden case packing size:
Main components: L 560 * W 560 * H 605 mm
G.W. : 40 KG, N.W. : 20 KG
Air compressor: L 670* W 700 * H 1160 mm
G.W. : 100 KG, N.W. : 64 KG
Reviews