Defi Xpress®
Defi Xpress® is a lightweight, portable, and durable defibrillator designed for fast, reliable response in hospitals and clinics. Combining manual defibrillation, AED, monitoring, and optional pacing in one device, it ensures lifesaving efficiency when every second counts.
With a clear 8-inch display, quick charging under 7 seconds, and optional SpO₂, NIBP, and EtCO₂ modules, Defi Xpress® delivers advanced functionality in a user-friendly design. Multilingual support and compact portability make it ideal for professional emergency care worldwide.
Defi Xpress® — Technical Specifications
Display
- Screen Type: High-resolution display
- Screen Size: 8″ (20.3 cm) diagonal
- Sweep Speed: 25 mm/s
- Displayed Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO₂, AED
- On-screen Controls: Alarm selection & limits, delivered energy
Defibrillator
- Waveform: Biphasic
- Charge Time: < 7 seconds (with a new fully charged battery)
- Energy Display: Shows both selected and delivered energy
- Charge Prompts: Voice and visual prompts
- Electrode Impedance Measurement Range: 0–250 Ω
ECG Monitoring
- Patient Connection: 3-lead or 5-lead ECG cable, paddles
- Lead Selection: Paddles, I, II, III, aVR, aVL, aVF, V
- ECG Gain (size): 0.25, 0.5, 1, 1.5, 2, 4 cm/mV
- Heart Rate Range: 20–300 BPM
- Heart Rate Alarm: User-selectable (On/Off)
- Smart Alarms: Beeper/voice prompts indicate shockable rhythm
Battery
- Type: Rechargeable Ni-MH battery, 12 V
- Operating Time (new, fully charged): Up to 60 full-energy discharges OR minimum 3 hours continuous ECG monitoring (actual time varies with functions)
Optional Modules
- SpO₂
- Measurement Range: 30%–100%
- Accuracy: ±2% (80%–90%), ±5% (other ranges)
- Alarm: User-set high/low limits
- Alarm Accuracy: ±10% within setting values
- Alarm Time Accuracy: < 12 seconds
- EtCO₂ (optional)
- NIBP (optional)
Recorder / Printer
- Paper: 50 mm thermal
- Print Speeds: 12.5, 25, 50 mm/s
- Print Modes: Manual or automatic (user-configurable)
- Automatic Recording: 9-second recording triggered by alarm activation, defibrillator charge, or discharge
- On/Off Control: Front panel and paddle
- Printing Method: High-resolution thermal print head
AED Mode
- Function: Auto-analyze and charge (up to 3 cycles) with programmable auto energy level selection
- Prompts: Voice and visual prompts
- Shockable Rhythms Defined In Unit:
- Ventricular fibrillation (VF) with amplitude ≥ 200 µV
- Ventricular tachycardia (VT) with rate ≥ 140 BPM
- QRS complex duration ≥ 140 ms
Manual Mode
- Energy Selection (Joules): 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J
- Synchronized Mode: Synchronizes pulse to patient R-wave (“SYNC” displayed)
- Charge Control: Front panel and paddle key
General
- Languages Available: English, Russian, Spanish, Chinese, Turkish
- Optional Accessories/Features: ECG monitoring paddles, SpO₂, NIBP, EtCO₂, PC software
- Design: Compact, lightweight, durable for hospital and clinic use